Error code occurred during ECU upgrade (1000-01-1010)

Symptom: ECU upgrade in progress, error code [1000-01-1010] occurs

Cause: Socket connection failure with gateway (non-CCU type) to perform Ethernet event

 

Resolution:

If error code 1000-01-1010 is shown, please check the following requirements are set properly. 

 

  1. Does the upgrade that you are going to do suppoprt ethernet communication? 
  1. If required, is VCI 2 or 3 connected to the tablet via wired connection? 
  1. If wired, is static IP set on the tablet network settings?

4. (Optional)It is necessary to check version of Google Play System Update: refer to the Further Resources below.

5. (Optional)After removing the vehicle power connector, proceed with the installation work 5 minutes later and retry the ECU upgrade.

 

Further Resources:

How to fix Ethernet ECU upgrade not possible on some tablets with Android OS 13 or higher – User Guide & Download

What to Do When ECU Upgrade Fails

How to send the error log report on GDS Smart/KDS2.0

How to get ECU logs from your tablet on GDS Smart/KDS2.0

 

In case the above workaround doesn't resolve the issue, please contact your distributor or GIT assistance at following email for further support.

 