Type | ☐Notification ☐Repair ☑Guidance | Regions Covered |
Devices |
☑ GDS Smart/Mobile ☑ GNESIS Smart/Mobile ☑ KDS 2.0/KDS 1.0 ☑ ULT-100 |
ALL |
Date Issued | (KST) 21-Jan-2025 | Duration |
Subject | Possible Causes of the "Air Vent Check" Message | ☐ Temporary ☑ Permanent |
Symptom:
The "Air Vent Check" message may appear in the following situations:
-
The pressure regulator is missing from the air injection adapter mounting area on the upper case of the EV battery pack.
- Solution: Ensure the pressure regulator is properly installed.
-
The silicone O-ring at the bottom of the air injection adapter is missing.
- Solution: Reassemble the silicone O-ring correctly and remove any foreign substances from the mounting surface.
-
Poor assembly of the pressure regulator installed on the upper case of the battery, preventing proper seating on the bottom surface.
- Cause: The pressure regulator may be clogged with foreign substances or improperly assembled.
- Solution: Clean the mounting area of the pressure regulator and replace it with a new one if necessary.