Possible Causes of the "Air Vent Check" Message

Type ☐Notification ☐Repair ☑Guidance Regions Covered
Devices

☑ GDS Smart/Mobile

☑ GNESIS Smart/Mobile

☑ KDS 2.0/KDS 1.0

☑ ULT-100

ALL
Date Issued (KST) 21-Jan-2025 Duration
Subject Possible Causes of the "Air Vent Check" Message ☐ Temporary ☑ Permanent

 

Symptom:

 

The "Air Vent Check" message may appear in the following situations:

  1. The pressure regulator is missing from the air injection adapter mounting area on the upper case of the EV battery pack.

    • Solution: Ensure the pressure regulator is properly installed.
  2. The silicone O-ring at the bottom of the air injection adapter is missing.

    • Solution: Reassemble the silicone O-ring correctly and remove any foreign substances from the mounting surface.
  3. Poor assembly of the pressure regulator installed on the upper case of the battery, preventing proper seating on the bottom surface.

    • Cause: The pressure regulator may be clogged with foreign substances or improperly assembled.
    • Solution: Clean the mounting area of the pressure regulator and replace it with a new one if necessary.