Possible Causes of the "Air Vent Check" Message

Type ☐Notification ☐Repair ☑Guidance Regions Covered
Devices

☑ GDS Smart/Mobile

☑ GNESIS Smart/Mobile

☑ KDS 2.0/KDS 1.0

☑ ULT-100

ALL
Date Issued (KST) 21-Jan-2025 Duration
Subject Possible Causes of the "Air Vent Check" Message ☐ Temporary ☑ Permanent

 

Symptom:

 

The "Air Vent Check" message may appear in the following situations:

  1. The pressure regulator is missing from the air injection adapter mounting area on the upper case of the EV battery pack.

          • Solution: Ensure the pressure regulator is properly installed.
  2. The silicone O-ring at the bottom of the air injection adapter is missing.

          • Solution: Reassemble the silicone O-ring correctly and remove any foreign substances from the mounting surface.
  3. Poor assembly of the *pressure regulator installed on the upper case of the battery, preventing proper seating on the bottom surface.

          • Cause: The pressure regulator may be clogged with foreign substances or improperly assembled.
          • Solution: Clean the mounting area of the *pressure regulator and replace it with a new one if necessary.

             